4U Tank

4U MIDAS XCI™ ALL-IN-ONE TANK

Our All-in-One Tank cools up to 7.5 kW and fits almost anywhere, including secure outdoor locations.

Maximum Efficiency in a Compact Footprint

Midas Immersion Cooling saves 48% power, costs 50% less, and requires half the space of air-cooling systems. The modular design allows quick deployment, scalability, easy maintenance, and low costs.

-

Patented technology prevents hot spots, temperature fluctuations, and enhances efficiency.

-

Provides up to 7.5 kW of heat dissipation capacity.

-

All-in-One Tank fits almost anywhere, including secure outdoor locations.

-

Immersion cooling eliminates fan failures, noise, contaminants, and corrosion in data centers.

-

Modular design allows quick deployment and scalability with easy maintenance.

Exceptional Reliability

MIDAS XCI™ eliminates many of the most common causes of computing equipment failure:

Server Fan Failure or Replacement Fans are removed before immersion which reduces energy consumption and eliminates fan issues
Air Quality Dust is not present in immersion systems and zinc whiskers are prevented
Overheating Heat is transferred more than 1,200 times more efficiently than in air
Temperature Swings Dielectric fluid circulates for uniform heat removal
Corrosion Oxidation does not occur in the immersion fluid
Noise Air conditioning and server fan noise is eliminated or significantly minimized
Limited IT load capacity Denser installations allow for higher computing performance in limited spaces
Server Fan Failure or Replacement
Fans are removed before immersion which reduces energy consumption and eliminates fan issues
Air Quality
Dust is not present in immersion systems and zinc whiskers are prevented
Overheating
Heat is transferred more than 1,200 times more efficiently than in air
Temperature Swings
MIDAS XCI™ system coolant circulates to distribute heat evenly
Corrosion
Oxidation does not occur in the immersion fluid
Noise
Air conditioning and server fan noise is eliminated or significantly minimized
Limited IT load capacity
Denser installations allow for higher computing performance in limited spaces

MIDAS XCI 4U Specifications

Heat Dissipation Capacity 7.5 kW
immersion Server Capacity 4U
Additional Server Capacity No
Maximum Server Depth 30” / 762 mm
Dimensions 47”W x 47”L x 60”H / 1200 mm x 1200 mm x 1550 mm
System Power Consumption 1.8 COP*
Water Connection N/A
Water Requirements NONE
Ambient Heat Loss <0.5 kW
Liquid Volume 30 gal / 115.2 L
Tank Dry Weight 1250 #
Tank Weight with Dielectric 1490 #
Pressure Rating (Tank and Coolant) 1.85 psi / 12.75 kPa
Pump Rating 1 hp
Cooling Module Power Requirement 208-240 V / 1 ph / 10 A 60 Hz (customizable)
Network SNMP, SNTP and DHCP Client Enabled
Web Interface Yes