Our All-in-One Tank cools up to 7.5 kW and fits almost anywhere, including secure outdoor locations.
Maximum Efficiency in a Compact Footprint
Midas Immersion Cooling saves 48% power, costs 50% less, and requires half the space of air-cooling systems. The modular design allows quick deployment, scalability, easy maintenance, and low costs.

-
Patented technology prevents hot spots, temperature fluctuations, and enhances efficiency.
-
Provides up to 7.5 kW of heat dissipation capacity.
-
All-in-One Tank fits almost anywhere, including secure outdoor locations.
-
Immersion cooling eliminates fan failures, noise, contaminants, and corrosion in data centers.
-
Modular design allows quick deployment and scalability with easy maintenance.
MIDAS XCI™ eliminates many of the most common causes of computing equipment failure:
| Server Fan Failure or Replacement | Fans are removed before immersion which reduces energy consumption and eliminates fan issues |
|---|---|
| Air Quality | Dust is not present in immersion systems and zinc whiskers are prevented |
| Overheating | Heat is transferred more than 1,200 times more efficiently than in air |
| Temperature Swings | Dielectric fluid circulates for uniform heat removal |
| Corrosion | Oxidation does not occur in the immersion fluid |
| Noise | Air conditioning and server fan noise is eliminated or significantly minimized |
| Limited IT load capacity | Denser installations allow for higher computing performance in limited spaces |
| Server Fan Failure or Replacement |
|---|
| Fans are removed before immersion which reduces energy consumption and eliminates fan issues |
| Air Quality |
| Dust is not present in immersion systems and zinc whiskers are prevented |
| Overheating |
| Heat is transferred more than 1,200 times more efficiently than in air |
| Temperature Swings |
| MIDAS XCI™ system coolant circulates to distribute heat evenly |
| Corrosion |
| Oxidation does not occur in the immersion fluid |
| Noise |
| Air conditioning and server fan noise is eliminated or significantly minimized |
| Limited IT load capacity |
| Denser installations allow for higher computing performance in limited spaces |
| Heat Dissipation Capacity | 7.5 kW |
| immersion Server Capacity | 4U |
| Additional Server Capacity | No |
| Maximum Server Depth | 30” / 762 mm |
| Dimensions | 47”W x 47”L x 60”H / 1200 mm x 1200 mm x 1550 mm |
| System Power Consumption | 1.8 COP* |
| Water Connection | N/A |
| Water Requirements | NONE |
| Ambient Heat Loss | <0.5 kW |
| Liquid Volume | 30 gal / 115.2 L |
| Tank Dry Weight | 1250 # |
| Tank Weight with Dielectric | 1490 # |
| Pressure Rating (Tank and Coolant) | 1.85 psi / 12.75 kPa |
| Pump Rating | 1 hp |
| Cooling Module Power Requirement | 208-240 V / 1 ph / 10 A 60 Hz (customizable) |
| Network | SNMP, SNTP and DHCP Client Enabled |
| Web Interface | Yes |