12U Tank

12U MIDAS XCI™ MINI TANK

Perfect for the edge, IoT, data closets, POC and testing environments.

Maximum Power in a Small and Flexible Enclosure

The Midas 12U tank provides up to 18 kW of heat dissipation (cooling loop dependent) which significantly reduces the cost of energy to cool the equipment. Midas XCI™ tanks can be individually managed and configured based on each customer’s prioritized needs.

 

-

Portability that provides plug and play features

-

Provides up to 18 kW of heat dissipation

-

Can be remotely deployed in locations such as a branch office or high-risk zone

-

MIDAS 12U XCI™ Mini Tank enables distributed workloads, minimizing downtime and increasing speed of response

-

Designed for use in technology closets or other space-constrained locations where computing equipment resides and must be efficiently cooled

Exceptional Reliability

MIDAS XCI™ eliminates many of the most common causes of computing equipment failure:

Server Fan Failure or Replacement Fans are removed before immersion which reduces energy consumption and eliminates fan issues
Air Quality Dust is not present in immersion systems and zinc whiskers are prevented
Overheating Heat is transferred more than 1,200 times more efficiently than in air
Temperature Swings Dielectric fluid circulates for uniform heat removal
Corrosion Oxidation does not occur in the immersion fluid
Noise Air conditioning and server fan noise is eliminated or significantly minimized
Limited IT load capacity Denser installations allow for higher computing performance in limited spaces
Server Fan Failure or Replacement
Fans are removed before immersion which reduces energy consumption and eliminates fan issues
Air Quality
Dust is not present in immersion systems and zinc whiskers are prevented
Overheating
Heat is transferred more than 1,200 times more efficiently than in air
Temperature Swings
MIDAS XCI™ system coolant circulates to distribute heat evenly
Corrosion
Oxidation does not occur in the immersion fluid
Noise
Air conditioning and server fan noise is eliminated or significantly minimized
Limited IT load capacity
Denser installations allow for higher computing performance in limited spaces
12U MIDAS XCI™ MINI TANK, 12U TANK

MIDAS XCI 12U Specifications

Heat Dissipation Capacity 6-18 kW
immersion Server Capacity 12 U
Additional Server Capacity 4 U for Power and/or Network Distribution
Maximum Server Depth 36.5” / 0.93 m
Dimensions 8”W x 44”L x 58”H / 0.71 m x 1.12 m x 1.47 m
System Power Consumption 0.1 - 1 kW
Water Connection 1” NPT
Water Requirements Varies with site requirements
Ambient Heat Loss <0.5 kW
Liquid Volume 100 gal / 378 L
Tank Dry Weight 250 lb / 113 kg
Tank Weight with Dielectric 1000 lb / 453 kg
Module Dry Weight 180 lb / 82 kg
Pressure Rating (Tank and Coolant) 1.75 psi / 12 kPa
Pressure Rating (Tank, 12 servers & Coolant) 2.15 psi / 14.8 kPa
Pump Rating 1 hp
Cooling Module Power Requirement 208-240 V / 1 ph / 10 A 60 Hz (customizable)
Network SNMP, SNTP and DHCP Client Enabled
Web Interface Yes