Perfect for the edge, IoT, data closets, POC and testing environments.
Maximum Power in a Small and Flexible Enclosure
The Midas 12U tank provides up to 18 kW of heat dissipation (cooling loop dependent) which significantly reduces the cost of energy to cool the equipment. Midas XCI™ tanks can be individually managed and configured based on each customer’s prioritized needs.
-
Portability that provides plug and play features
-
Provides up to 18 kW of heat dissipation
-
Can be remotely deployed in locations such as a branch office or high-risk zone
-
MIDAS 12U XCI™ Mini Tank enables distributed workloads, minimizing downtime and increasing speed of response
-
Designed for use in technology closets or other space-constrained locations where computing equipment resides and must be efficiently cooled
MIDAS XCI™ eliminates many of the most common causes of computing equipment failure:
Server Fan Failure or Replacement | Fans are removed before immersion which reduces energy consumption and eliminates fan issues |
---|---|
Air Quality | Dust is not present in immersion systems and zinc whiskers are prevented |
Overheating | Heat is transferred more than 1,200 times more efficiently than in air |
Temperature Swings | Dielectric fluid circulates for uniform heat removal |
Corrosion | Oxidation does not occur in the immersion fluid |
Noise | Air conditioning and server fan noise is eliminated or significantly minimized |
Limited IT load capacity | Denser installations allow for higher computing performance in limited spaces |
Server Fan Failure or Replacement |
---|
Fans are removed before immersion which reduces energy consumption and eliminates fan issues |
Air Quality |
Dust is not present in immersion systems and zinc whiskers are prevented |
Overheating |
Heat is transferred more than 1,200 times more efficiently than in air |
Temperature Swings |
MIDAS XCI™ system coolant circulates to distribute heat evenly |
Corrosion |
Oxidation does not occur in the immersion fluid |
Noise |
Air conditioning and server fan noise is eliminated or significantly minimized |
Limited IT load capacity |
Denser installations allow for higher computing performance in limited spaces |
Heat Dissipation Capacity | 6-18 kW |
immersion Server Capacity | 12 U |
Additional Server Capacity | 4 U for Power and/or Network Distribution |
Maximum Server Depth | 36.5” / 0.93 m |
Dimensions | 8”W x 44”L x 58”H / 0.71 m x 1.12 m x 1.47 m |
System Power Consumption | 0.1 - 1 kW |
Water Connection | 1” NPT |
Water Requirements | Varies with site requirements |
Ambient Heat Loss | <0.5 kW |
Liquid Volume | 100 gal / 378 L |
Tank Dry Weight | 250 lb / 113 kg |
Tank Weight with Dielectric | 1000 lb / 453 kg |
Module Dry Weight | 180 lb / 82 kg |
Pressure Rating (Tank and Coolant) | 1.75 psi / 12 kPa |
Pressure Rating (Tank, 12 servers & Coolant) | 2.15 psi / 14.8 kPa |
Pump Rating | 1 hp |
Cooling Module Power Requirement | 208-240 V / 1 ph / 10 A 60 Hz (customizable) |
Network | SNMP, SNTP and DHCP Client Enabled |
Web Interface | Yes |